Megger LTW335-EU-AU Loop Impedance Tester - Two Wire Non Tripping with 50 to 440V testing; Max Z and Live & PE
Megger LTW335-EU-AU Loop Impedance Tester - Two Wire Non Tripping with 50 to 440V testing; Max Z and Live & PE
The LTW300 two-wire non-tripping loop impedance testers verify the loop impedance of a live electrical circuit i.e. without the need to disconnect the electrical supply. The new LTW300 series instruments offer a two-wire loop testing solution that does not trip 30 mA RCDs and can be used on a wide range of voltages. The new LTW300’s offer a range of features to make earth loop testing safer and easier. The LTW300 series of instruments are guaranteed not to trip working RCDs of ?30 mA using the no-trip loop test. Three-phase circuits with RCD protection can also be tested as all test modes operate on single and three phase systems. The loop test runs for approximately 10 seconds with an additional 10 seconds if the instrument detects electrical noise on the supply that could otherwise cause errors on the test result.For supplies that do not have an RCD fitted the high current test should be used as there is no risk of tripping and RCD. Noise detection (only applies to no-trip tests). The LTW300 also uses sophisticated noise detection circuitry which continually monitors the supply whilst performing a loop test to ensure the accuracy of the result has not been compromised by the effects of electrical noise from plant and services
Features |
|
---|---|
Brand | Megger |
Range Name | LVI |
Standard Pack Size | 1 |
UNSPSC Class | 41113600 |
UOM | EA |
Vendor Product | LTW335-EU-AU |
Current | 20K Amp |
Dimensions | 203 x 148 x 78mm |
Display Type | Digital |
Frequency | 25/99.9 Hz |
Power Supply | Alkaline |
Please Note | Non-Trip MAXZ R1+R2 2 Watt 440 Volt |
Product Type | simple |
Temperature | -10 to 50 deg C |
Voltage | 50-440 Volt |
Description
The LTW300 two-wire non-tripping loop impedance testers verify the loop impedance of a live electrical circuit i.e. without the need to disconnect the electrical supply. The new LTW300 series instruments offer a two-wire loop testing solution that does not trip 30 mA RCDs and can be used on a wide range of voltages. The new LTW300’s offer a range of features to make earth loop testing safer and easier. The LTW300 series of instruments are guaranteed not to trip working RCDs of ?30 mA using the no-trip loop test. Three-phase circuits with RCD protection can also be tested as all test modes operate on single and three phase systems. The loop test runs for approximately 10 seconds with an additional 10 seconds if the instrument detects electrical noise on the supply that could otherwise cause errors on the test result.For supplies that do not have an RCD fitted the high current test should be used as there is no risk of tripping and RCD. Noise detection (only applies to no-trip tests). The LTW300 also uses sophisticated noise detection circuitry which continually monitors the supply whilst performing a loop test to ensure the accuracy of the result has not been compromised by the effects of electrical noise from plant and services